Reference:
i
- When installing external control elements or safety and signal
equipment, the relevant instructions must be observed.
- The safety elements that are installed are activated by the
express programming.
7.1
Connection of control elements
• Connect any available accessories.
XB02 External control elements and safety equipment
7.2
Terminal XB02
SB1
Impulse button
SB4
Opening contact for hold circuit (e. g. stop button, wicket
door contact)
1
24 V DC (max. 50 mA)
2
Connect potential-free impulse button
3
0V / GND
4
Hold circuit
70
Two-wire photocell connection
71
Two-wire photocell connection
7.3
For connection of external photocell
1
24 V DC (max. 50 mA)
2
Connect potential-free impulse button
3
0V / GND
70
External two-wire photocell connection
71
External two-wire photocell connection
S1
Potential-free opening contact for photocell
Advice:
An opening contact that is connected is activated after a power
interruption. An activated opening contact can only be deacti-
vated by a reset.
7.4
• Connect the drive system to the mains power supply.
7.5

Overview of the control unit

A
Seven segment display
B
MINUS button (e.g. to decrease parameters when
programming)
C
PLUS button (e.g. to increase parameters when
programming)
D
P-button (e.g. to save parameters)
Displays in operating mode
Photocell beam or bottom safety edge device interrupted
Door moves in OPEN direction
Door is in OPEN position
Door moves in CLOSE direction
Door is in CLOSED position
Continuous activation of an external control element
Remote control unit is used
Ready for operation
Express programming
Operator system is in operating mode
10
1x >2s <10s
Start express programming /
P
programme OPEN door position
Drive door to OPEN position as far as the
limit stop
1x <1s
Save OPEN door position /
P
programme CLOSED door position
Drive door to CLOSED position
Correct the CLOSED door position
with (+) and (-)
1x <1s
Save CLOSED door position /
P
programme remote control unit
Use the hand transmitter
Release the hand transmitter button
1x <1s
Save the remote control settings /
P
End the express programming procedure
Function test
Learning run for determining the driving power
Check:
After express programming and after making changes to the
programming menu, the following learning runs and checks must
be carried out.
• Operate the operator system (with the door coupled) to drive
the door once from the CLOSED position to the OPEN position
and back to the CLOSED position without interruption.
Test:
After pressing the (+) button:
The door must open and travel to the saved
OPEN end position.
After pressing the (-) button:
The door must close and travel to the saved
CLOSED end position.
After pressing the hand transmitter button:
The operator system must move the door in
either the OPEN or CLOSE direction.
After pressing the hand transmitter button while
the operator system is running:
The operator system must stop.
When the button is pressed again,
the operator system moves in the opposite
direction.
Advice:
In the event of a photocell beam failure the door can be closed in
deadman operation using the (-) button.
GDO 500S/L - 700S/L (#91376)