Menu: Timing programs
Menu: Vacations
Different switching programs are
available for the heating circuits and
the preparation of DHW.
These are set to the operating mode
"Automatic", and they control the
change of the temperature level (and
the corresponding target values) for
the different switching times that have
been set.
Entry of switching times
The switching times can be set in
combination, namely for several days
jointly, or for separate times on single
days. Through a pre-selection of a
groups, such as for instance Mon...Fr.
and Sat...Sun, which have the same
switching times, the setting of switching
programs is shortened substantially.
Copy day to

Standard program

Vacations
By using the vacations program,
heating circuits can be switched to a
selectable operating level by calendar
date. Heating, however, does not
resume on the ending day.
Only on the next day is heating
switched to the comfort target value
and according to the timer program.
Line no.
HC2 3/HCP 4/DHW
HC1
500
520
540
560
501
521
541
561
502
522
542
562
503
523
543
563
504
524
544
564
505
525
545
565
506
526
546
566
Line no.
515, 535, 555, 575
When only one weekday is selected
as a preselected day, then the time
phases can be copied to other
weekdays.
Line no.
516, 536, 556, 576
All timer switching programs can be
reset to the factory settings.
Each timer switching program has its
own operating line for such a reset.
Line no.
Operating line
VG2
VG1
642
652
Start
653
End
643
648
658
Operating level
Frost protection
Reduced
-
The vacation program can only be
used in automatic operating mode.
Operating line
Factory setting
Preselection
Mon - Sun
Mon - Sun
Mon - Fri
Sat - Sun
Mon . . . Sun
1. Phase ON
6 : 00
1. Phase OFF
22 : 00
2. Phase ON
- - : - -
2. Phase OFF
- - : - -
3. Phase OFF
- - : - -
3. Phase OFF
- - : - -
Operating line
Copy day to
Operating line
Standard values
Note
Individual settings are lost during a
reset!
Factory setting
- - : - -
- - : - -
Frost protection
13