Operation
Main functions of the control panel
Button
Action
Setting up the required
room temperature
Setting the required room temperature
for HC1 or HC2
Switching warm water operations ON
or OFF
Change operating mode
Control stop function
Display of various
information
Operating mode according to
target values that are
set manually
Change of the factory setting
for boiler temperature
De-aeration function
Activation of chimney sweep function
Short-term reduction of room
temperature at QAA75 / 78
Reset button
RESET
Procedure
HC2 jointly with HC1
Turn the rotating button left or right
Turn the rotating button again for
storing with OK button
or wait for 5 sec.
or push
or
2nd HC independent of HC1
Turn rotating button left/right
Then push OK
Turn rotating button left/right
Save with OK button
or wait for 5 sec.
or push
Push button
Factory setting
1 x short push of button and then
once more, short push of button
1 x push button (> 3 sec)
push button once more (> 3 sec)
1 x push button
push button again
push button again
Push button
short push of button
short push of button
short push of button
Rotating button turn -/+
short push of button
short push of button
short push of button
1 x push button (> 3 sec)
push button once more (> 3 sec)
Push button (> 3 sec)
push button once more (> 3 sec)
Push button
push button again
Push button (< 3 sec.) push button
again > 3 sec.
= Confirmation
Display / Function
comfort target value with blinking temperature display
blinking temperature display in steps of 0.5° centigrade, from 10.0 to 30°C
Comfort value active
Comfort value not active
- Basic display appears after 3 sec.
Select heating circuit
Heating circuit active
blinking temperature display in steps of 0.5° centigrade, from 10.0 to 30°C
Comfort target value active
Comfort target value not active
- Basic display appears after 3 sec.
Warm water operation ON / OFF
(segmented bar under symbol for warm water visible/invisible)
-
ON: Warm water preparation according to switching program
-
OFF: No warm water preparation
-
Safety function active
Automatic operating mode ON, with:
-
heating operation according to timer program
-
Temperature target values according to heating program
-
Safety function active
-
Summer/Winter - automatic switching active
-
ECO functions active
(segmented bar under corresponding symbol visible)
Continuous COMFORT heating ON, with:
-
Heating operation without timer program, at comfort target value
-
Safety function active
Continuous REDUCED heating ON, with:
-
Heating operation without timer program, at reduced target value
-
Safety function active
-
Summer/Winter - automatic switching active
-
ECO functions active
Automatic safety mode ON, with:
-
Heating operations switched off
-
Temperature according to frost protection value
-
Safety function active
304: Control stop function
Basic display appears after 3 sec.
INFO section is displayed
- Boiler status
- Room temperature
- Room temperature minimum
- Warm water status
- Room temperature maximum
- Status heating circuit 1
- Outdoor temperature
- Status heating circuit 2
- Minimum outdoor temperature
- Maximum outdoor temperature
- Time / date - Water temperature 1
- Error message
- Boiler temperature
- Maintenance report
- Flow temperature
(Display of the information lines depends on the configuration)
Back to basic display; INFO segment is suppressed
Manual operating mode ON (spanner symbol is visible)
- Heating operations at preset boiler temperature (factory setting = 60°C)
301: Manual operation mode
operation?
Blinking temperature display
Set required target value
Boiler status
Manual operating mode OFF (spanner symbol disappears)
312: De-aeration function ON
De-aeration function OFF
Chimney sweep function ON
Chimney sweep function OFF
Heating at reduced target value
Heating at comfort target value
Facility is manually locked, unreleased equipment is unlocked, alarm bell
disappears
= Abort or back to basic display
Set target value
Set target value for manual
7