Operating elements

Operating elements
Filling and de-aeration
Legend:
A On/Off switch
B Back button (ESC)
C Room temperature control button
D Confirmation button (OK)
E Function button for manual
operation
F Chimney sweep function button
G Information button
H Reset button
I
Operation mode button for heating
circuit(s)
L Display
M Operating mode button for DHW
Operating mode button for DHW (M)
For switching on the DHW preparation
(Bar under the water crane in the
display)
Operation mode button for heating
circuit(s) (I)
For setting 4 different operating modes
for heating
Automatic clock: Automatic operation
according to timer program
Sun 24 hr: Heating at comfort target
value
Moon 24 hr: Heating at reduced value
Protection mode: Heating switched off -
frost protection active
Display (L)
Information button (G)
Retrieval of the following information,
without influence on the control
processes:
Temperatures, operating condition of
the heating facility/DHW, error reports
Room temperature control button
(C)
-
For changing the room comfort
temperature
-
With this rotating button, settings
can be selected and changed
during programming.
M
A
H
Confirmation button OK (D)
Back button ESC (B)
These two buttons are needed in
combination with the large rotating
button (- +) for the programming
and configuration of the control unit.
Settings, which cannot be changed
through the control elements, are
provided by means of programming.
By pushing the ESC button you always
go one step backward, whereby
modified values are not taken over.
To reach the next operating level, or
to store the changed values, you must
push the OK button.
Manual operation function button (E)
By pushing this button, the control
unit is set to manual mode, whereby
all pumps are running, the mixer is
no longer controlled and the burner is
set to 60°C. (Indicated by the spanner
symbol)
Chimney sweep function button (F)
Push this button shortly, to put the
boiler in the operating mode for
measuring emissions; renewed
pushing of the button deactivates
this function, or it is automatically
deactivated after 15 minutes (indicated
by the spanner symbol).
May only be operated by the chimney
sweep!
Reset button (H)
By pressing this button shortly, the
locked condition of the burner is
deactivated.
B
C
D
E
F
On/Off switch (A)
Position 0:
The entire facility and all connected
electrical components are without
electrical power. A protection against
frost is not ensured.
Position I:
The entire facility and all connected
electrical components are ready for
operation.
Filling and de-aeration of the
THISION S PLUS Compact V and the
heating facility
The heating facility is filled according to
the standard method.
The facility must have been deaerated,
both on the heating and the warm
water side.
The water pressure can be read off
in bar, either on the analog pressure
indicator or via the information button.
The boiler is ready for operation, as
soon as the heating facility has been
filled and deaerated.
After an appropriate period, the water
pressure should be checked and, if
necessary, water should be topped up.
(Note: Before topping up the water, first
fill the hose with water, which prevents
the entry of air into the heating system).
Use the pump de-aeration function to
remove all air from the pump and the
boiler: Hold down the E button for more
than 3 seconds. This function runs for
approximately 16 minutes.
During the initial commissioning, or
after filling or topping up the heating
facility, always first activate the de-
aeration function.
I
L
G
5