Only the additional latchbolts are retracted
GU-SECURY "AutomaticDay" and GU-SECURY "AutomaticTE" with A-opener:
No error, function is intended.
Defective central lock case:
Please contact GU.
No „Servo" function
Check connecting rods can move freely.
Check the key can turn easily.
If a SECUREconnect has been used, the following must be noted:
If the doors have been open for an extended period of time, they have to be closed for at
least 15 seconds (tappets are in contact with the contact plates) in order to re-establish
the A-opener servo's full range of functions.
Motor running again only after a few seconds
The A-opener / A-opener servo is blocked for max. 15 seconds after a fast succession of
several opening and closing cycles so that the capacitors can be adequately recharged.
9
GU Customer services
-
Installation of motor drive and start-up
-
Annual inspection in compliance with the prevailing standards and regulations
-
Maintenance and repair works
-
Retrofi tting or changing existing door assemblies.
For clarifying any technical questions please contact our aftersales service.
10 Disposal
The device contains electrical parts and must be disposed of in compliance with the legal
regulations.
11 Declaration of Performance
The following Declaration of Performance applies to this product:
0004-CPR-GU-BKS-Ferco
Declarations of Performance can be found at the GU
website "www.g-u.com" in the menu item
"Construction Products Regulation / CPR" under "Services":
www.g-u.com/en/services/construction-products-regulation.html
04.2016 | G32082 | Designed in Germany