Herunterladen Inhalt Inhalt Diese Seite drucken

Filters - Pitco frialator MG14S-C/MFD Serviceanleitung

Elektrische fritteuse mit filter, exklusiv für mcdonald’s hergestellt mcdonald's nur für den ce markt
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Filters:

PROBLEM
Red Return Valve is open but no A. Red Return Valve NOT fully open
pump sound can be heard
Drain valve is closed and the
computer has been reset but
still shows "DRAINING" or
"TURN OFF"
Drain Valve is OPEN, the oil
is draining slowly or not at all.
PROBABLE CAUSE
B. Filter Circuit Breaker may be tripped
C. Filter Motor Thermal Overload may
be tripped
D. Sensor switch may be loose or bad
A. Green Drain Valve is NOT fully
Closed
B. Sensor switch may be loose or bad
A. Green Drain Valve is NOT fully open
B. Drain is plugged with debris
7
CORRECTIVE ACTION
A. Pull slightly on the Red handle to check
that it is fully open.
B. Locate the circuit breaker and reset.
C. Push Red reset button located on end of
filter motor.
D. Check that the switch is tight in its
mounting. If switch is bad replace it.
A. Apply a little more pressure to the
Green Handle to check that it is
fully closed.
B. Check that the switch is tight in its
mounting. If switch is bad replace it.
A. Apply a little more pressure to the
Green Handle to check that it is fully
closed.
B. Use the Clean Out Rod from inside the
Fry Vat to clear the Drain Valve. If this
NOT clear the blockage, CLOSE the
Green Drain Valve and follow these
instructions for clearing the main drain
line.
CAUTION:
Some HOT oil may still come out when
the cap is removed.
Remove the two screw from the end
cap (Do NOT lose these.) Use the
Clean Out Rod to clear the main drain
tube. Install the end cap along with its
gasket and two screws. Do not
overtighten these screws.

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis