Cable set is equipped with a 125 A fuse. In case of a short circuit, fuse cuts circuit and
prevents any further damage.
After battery installation transfer battery bank data, via remote throttle, to on-board com-
puter (chapter 5.3, „Set-up mode") to be up to date about state of charge and range.
• Serial and parallel configured batteries must always have the same state
• Cable cross section for interconnection of batteries must be 25 mm².
• Firmly tighten srews of battery terminals for fixing to battery poles.
• Disconnect the battery when leaving the boat for a longer time.
5. Operation
5.1 Driving operation
To start the motor, switch it on, apply magnetic key and turn the tiller handle from the
stop-position into the desired direction.
1.
68
of charge. That is why you must use only the same type of batteries in
configurations (same capacity, same age, same manufacturer, same
state of charge) and fully charge each battery separately in your charger
before you connect it up. Differences in the state of charge can lead to
extremely high compensatory currents or overloads on the cables and
plugs or the battery itself. In extreme cases this could even cause fire or
injury.
Take care that battery poles are clean and corrosion free.
2.
3.