Menu - Program
1
2
3
1
Home/return
Return to standard control panel.
2
Selecting programs
- Program details
- Program list
- Program wizard
3
Recall of factory settings
Reset the chosen program to factory
settings.
Menu - Process setup
1
2
3
4
5
6
1
Home/return
Return to standard control panel.
2
Setting welding process
3
Sequences
Setting number of sequences.
(Sequence Repeat function =
two sequences).
4
Setting DUO Plus
parameters
TM
Efficiency (0-50% of set welding current (A)).
DUO Plus
time (s).
TM
5
Arc adjust
6
Gas
- Setting manual gas/IGC (not all versions)
- Gas test
- Calibration of IGC
Licence-dependent
QUICKGUIDE SIGMA SELECT GRAPHICAL
Menu - Wire feeder
1
2
3
4
5
1
Home/return
Return to standard control panel.
2
Wire inching forwards
3
Wire inching backwards
4
Gas test
5
Wire feeder activation
Menu - Machine Setup
1
2
3
4
1
Home/return
Return to standard control panel.
2
Language selection
3
Torch settings
Torch type. Selection of water cooling.
4
Machine settings
- Sequence trigger
- Cable compensation
- Lock level
- Time & date
- RCI (not all models)
- Setup Wizard
- Service
- About (software and licenses)