EN
• WARNING:
The machine must be always kept
on horizontal bases, in a safe and stable way.
> WATER SUPPLY
Water supply collection
Water supply from the water main
· Connect a supply hose (not included) to
the water inlet of the unit and to the water
supply.
· Open the water supply.
WARNING: (symbol) machine not suitable
for connection to the potable water mains.
The cleaner can only be connected to the wa-
ter mains if the water mains is separated by a
backflow preventer. Make sure that the hose
is at least Ø 13mm-1/2 inch and that it is rein-
forced.
• WARNING: Water that has flown through
backflow preventers is considered to be
nonpotable.
IMPORTANT: Only clean or filtered water
should be used for intake. The delivery of
the water intake tap should be equal to the
double of the maximum pump range.
- Minimum delivery rate: 30 l/ min.
- Maximum intake water temperature: 40°C
- Max inlet water pressure: 1Mpa
Place the cleaner as close to the water supply
system as possible.
Water supply from an open container
· Unscrew the coupling part for the water
inlet.
· Screw the suction hose with filter (not
included) onto the water connection of the
unit.
· Hang the filter in the container.
· Vent the unit before operation.
· Unscrew the high-pressure line at the high-
pressure outlet of the unit.
· Switch on the unit and let it run until water
free of bubbles emerges at the high-pressure
outlet.
· Switch off the unit and screw on the high-
pressure hose again.
Failure to comply with the above conditions
causes serious mechanical damage to the
pump and the loss of warranty cover.
18
> ELECTRICITY SUPPLY
- The appliance's electrical connection must
comply with the IEC 60364-1 standard.
IMPORTANT: Before
appliance, make sure that the nameplate
data are the same as those of the electrical
mains and that the socket is protected by a
differential security breaker with tripping
sensitivity below 0.03 A - 30 ms.
- If the appliance's plug is not compatible with
the socket, have the socket replaced with
another of suitable type by professionally
qualified staff.
- Never use the appliance in ambient
temperatures below 0° C if it is equipped
with a PVC (H VV-F) cable.
• XY WARNING: Inadequate extension cords
can be dangerous.
• XJ WARNING: If an extension cord is used,
the plug and socket must be of watertight
construction.
Information for supply may also be obtained
from the plug manufacturer.
230-240V
3G 2,5 mm2
max 20 m
USAGE
> UNPACKING
(see fig. B)
Take out the upper and the lower hooks, which fix
the cardboard box to the pallet, take the cardboard
box off, put two wheels of the machine on ground
and take the pallet off.
> DESCRIPTION OF THE MACHINE
(fig. A)
connecting
400-415V
4G 2,5 mm2
max 30 m