specialized dealer. Single phase or two-
phase connection requires a mains cable
of minimum 70°C temperature stability.
Cable has been provided with end
sleeves. According to IEC regulations use
for one-phase connection: mains cable 3
x 4mm² and for two-phase connection:
mains cable 4 x 2.5mm². Please respect
specific national regulations in the first
priority.
• You must have the means for
disconnection incorporated in the fixed
wiring.
Connection diagram hob
One-phase connection 220 V - 240 V ~
1
2
3
N
Insert the bridge between the
screws as shown.
Main power connection 1-phase
L
Wiring colours:
Yellow / green
N
Blue
L
Black or brown
L
N
PE
N
• You must have the connection and the
connecting links carried out as shown in
the connection diagram.
• The earth lead is connected to terminal
and must be longer than leads carrying
electric current.
• Secure the connecting cable with cable
clips or clamps.
Two-phase connection 400 V 2L-1N ~
1
2
3
N
Main power connection 2-phase
L1 L2 L3 N
Wiring colours:
Yellow / green
N
Blue
L1
Black
L2
Brown
17
L1
L2
N
PE