Maintenance tasks BD 50/40 RS
Dismantling the vacuum bar
Set programme selection to "Drive".
Turn key to "0" and remove it.
Pull out the suction hose from the vacu-
um bar.
1 Suction hose
2 Suction bar coupling
Pull out the suction hose from the vacu-
um bar.
Loosen the suction bar coupling.
Remove the vacuum bar.
Replace or turn vacuum lips
Dismantle the vacuum bar.
1 Lock nut
Unscrew the knurled nuts.
Remove the suction bar insert from the
bottom of the suction bar.
1 Vacuum lip
2 Suction bar insert
Remove the vacuum lips from the suc-
tion bar insert.
Note:
The vacuum lip can be turned around 3
times until all edges are worn. Then a new
vacuum lip is required.
Reverse the suction lip or replace it and
rehook it into the hooks of the suction
bar insert.
Place the suction bar insert into the suc-
tion bar.
Screw on the knurled nuts and tighten
them.
Replacing the disk brushes
Lift the cleaning head.
Turn key to "0" and remove it.
Turn the unlocking lever of the sliding
brush in an anti-clockwise direction -
the brushes will fall downward and can
be pulled outward at the bottom of the
device.
Hold the new brush under the cleaning
head.
Turn the unlocking lever of the sliding
brush in clockwise direction and press
the brush upward.
Release the unlocking lever and check
that the brush is sitting properly.
Maintenance tasks - all types
Cleaning the floater
1 Sieve with floater ball
2 Pipe
Clean the sieve from the outside and
rinse it.
Check the mobility of the floater ball.
If it is too dirty:
Hold the pipe firmly and pull out the
sieve from the pipe.
Clean sieve and ball.
Hold the pipe firmly and reinsert the
sieve.
Frost protection
In case of danger of frost:
Empty the fresh and dirt water reser-
voirs.
Store the appliance in a frost-protected
room.
Faults
Danger
Risk of injury! Before carrying out any tasks
on the machine, set the main key to "0" and
remove it. Pull out the battery plug.
Warning
Suction turbine will continue to run for a
while after switch-off. Carry out mainte-
nance tasks only after the suction turbine
has come to a halt.
In case of faults that cannot be remedied
using the table below please contact the
customer service.
7
-
EN
21