Herunterladen Inhalt Inhalt Diese Seite drucken

Overview; Device Elements; Operating Field; Colour Coding - Kärcher HDS 5/12 C Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für HDS 5/12 C:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

Overview

Device elements

Figure 1
1 Support for spray lance
2 Manometer
3 Recess for detergent suction hose
4 Recessed grip (both sides)
5 Connection for water supply with filter
6 Water supply set
7 High-pressure connection EASY!Lock
8 High pressure hose EASY!Lock
9 Spray lance EASY!Lock
10 Marking of the nozzle
11 Triple nozzle EASY!Lock
12 Pouring vent for detergent
13 Steering roller with fixed position brake
14 Fuel sieve
15 Safety lever
16 Power supply
17 Trigger
18 Tool bag
19 Safety latch of the hand spray gun
20 Trigger gun EASY!Force
21 Pouring vent for fuel
22 Dosage valve for detergent

23 Operating field

24 Storage for hand spray gun
25 Step depression
26 Handle
27 Nameplate
28 Cover lock
29 Storage compartment for accessories
30 Burner
31 Recess for spray pipe
32 Cover
33 Backflow valve of the detergent infeed
34 Oil tank
35 Oil drain screw
36 Detergent suction hose with filter
37 Fuel filter
38 Fastening clamp
39 Hose (soft damping system) of the wa-
ter shortage safeguard
40 Water shortage safeguard
41 Sieve in the water shortage safeguard
42 Fine filter (water)
18
Figure 2
A Power switch
1 Indicator lamp for detergent
2 "Ready for use" indicator lamp
3 Fuel indicator lamp
– The operating elements for the cleaning
process are yellow.
– The controls for the maintenance and
service are light gray.

Symbols on the machine

High-pressure jets can be danger-
ous if improperly used. The jet
may not be directed at persons, animals, live
electrical equipment or at the appliance itself.
Risk of electric shock!
Only electricians or authorised
technicians are permitted to
work on parts of the plant.
Risk of burns on account of hot
surfaces!
Risk of poisoning! Do not inhale
exhaust fumes.
According to applicable regula-
tions, the appliance must never be
used on the drinking water net
without a system separator. En-
sure that the connection of your building
water installation on which the high-pres-
sure cleaner is operated is equipped with a
system separator pursuant to EN 12729
Type BA.
Water that was flowing through a system
separator is considered non-drinkable.
CAUTION
Always connect the system separator to
the water supply, never directly to the appli-
ance!
– 2
EN
Operating field

Colour coding

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis