CYLINDER MAY EXPLODE IF DAMAGED: Use only compressed gas cylinders containing the
correct shielding gas for the process used and properly operating regulators designed for the gas and
pressure used. Always keep cylinders in an upright position securely chained to a fixed support. Do
not move or transport gas cylinders with the protection cap removed. Do not allow the electrode,
electrode holder, work clamp or any other electrically live part to touch a gas cylinder. Gas cylinders
must be located away from areas where they may be subjected to physical damage or the welding
process including sparks and heat sources.

Installation and Operator Instructions

Read this entire section before installation or operation
of the machine.
Location and Environment
This machine can operate in harsh environments.
However, it is important that simple preventative
measures are followed to assure long life and reliable
operation:
Do not place or operate this machine on a surface
with an incline greater than 15° from horizontal.
Do not use this machine for pipe thawing.
This machine must be located where there is free
circulation of clean air without restrictions for air
movement to and from the air vents. Do not cover
the machine with paper, cloth or rags when
switched on.
Dirt and dust that can be drawn into the machine
should be kept to a minimum.
This machine has a protection rating of IP23. Keep
it dry when possible and do not place it on wet
ground or in puddles.
Locate the machine away from radio controlled
machinery. Normal operation may adversely affect
the operation of nearby radio controlled machinery,
which may result in injury or equipment damage.
Read the section on electromagnetic compatibility in
this manual.
Do not operate in areas with an ambient
temperature greater than 40°C.
Input Supply Connection
Check the input voltage, phase, and frequency supplied
to this machine before turning it on. The allowable input
voltage is indicated in the technical specification section
of this manual and on the rating plate of the machine.
Be sure that the machine is grounded.
Make sure the power available at the input connection is
adequate for normal operation of the machine. The fuse
rating and cable sizes are both indicated in the technical
specification section of this manual.
The machines:
V145:
(230Vac, single phase)
V145 2V:
(115 / 230Vac, single phase)
are designed to operate on engine driven generators as
long as the auxiliary can supply adequate voltage,
frequency and power as indicated in the "Technical
Specification" section of this manual. The auxiliary
supply of the generator must also meet the following
conditions:
Vac peak voltage: below 205V (for 115Vac input) or
410V (for 230Vac input).
Vac frequency: in the range of 50 and 60 Hertz.
RMS voltage of the AC waveform:
V145:
V145 2V:
It is important to check these conditions because many
engine driven generators produce high voltage spikes.
Operation of this machine with engine driven generators
not conforming to these conditions is not recommended
and may damage the machine.
ARFU (Auto-Restore FUse)
The dual input voltage machine is provided with the
ARFU device. It operates only when the input is
connected to the 115Vac mains and protects from input
overcurrent. When active, the "Thermal LED" lits (see
"Controls and Operational Features" section).
Note: The ARFU device operates independently from
the machine's duty-cycle.

Output Connections

A quick disconnect system using Twist-Mate
plugs is used for the welding cable connections. Refer
to the following sections for more information on
connecting the machine for operation of stick welding
(MMA) or TIG welding.
Stick Welding (MMA)
First determine the proper electrode polarity for the
electrode to be used. Consult the electrode data for this
information. Then connect the output cables to the
output terminals of the machine for the selected polarity.
Shown here is the connection method for DC(+) welding.
Connect the electrode
cable to the (+) terminal
and the work clamp to the
(-) terminal. Insert the
connector with the key
lining up with the keyway
and rotate approximately
¼ turn clockwise. Do not
over tighten.
For DC(-) welding, switch the cable connections at the
machine so that the electrode cable is connected to (-)
and the work clamp is connected to (+).
TIG Welding
This machine does not include a TIG torch necessary for
TIG welding, but one may be purchased separately.
Refer to the accessories section for more information.
Most TIG welding is done with DC(-) polarity shown
here. If DC(+) polarity is necessary switch the cable
connections at the machine.
A-2
230Vac ± 15%
115Vac or 230Vac ± 10%