Herunterladen Inhalt Inhalt Diese Seite drucken

Installation; Connection To Toilet; Connection To Discharge; Electrical Connection - DAB FEKALIFT 100-A Installation Und Wartung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 15
2.

INSTALLATION

2.1

Connection to toilet

FEKALIFT 100-A : the system must be connected to a toilet with horizontal outlet, as indicated in
fig.B page 62. To connect a washbasin it is necessary to use the input on the left side of the cover, looking
towards the grinder. Use the accessories supplied to connect the pipe.
FEKALIFT 200-A : the system must be connected to a toilet with horizontal outlet, closing the unused
lower side inlet, as indicated in fig.E-F page 62. To connect the auxiliary inputs see fig. F page 62.
2.2

Connection to discharge

Push the large end of the bend into the outlet of the appliance, turn it in the desired direction and fix it with a
clamp. For FEKALIFT 100-A push also mouth B onto the other end and fix it too with a clamp. Then
connect the discharge to the pump outlet and fix it with a clamp (fig. C-G page 62).
3.

ELECTRICAL CONNECTION

Attention: always respect the safety regulations!
The electrical connections must be made after assembly of the system!
Electrical installation must be carried out by an expert, authorised electrician, who takes on all
responsibility.
Connect the plug to a 10 – 16A 2-pole EARTHED socket.
The socket must supply only the power to the system; for FEKALIFT 100-A it must be connected to an
automatic safety switch and for FEKALIFT 200-A to a highly sensitive differential switch calibrated at
30 mA.
4.

COMMISSIONING

Connect to the power socket.
Flush the toilet once; the system must start automatically, FEKALIFT 100-A and FEKALIFT 200-A
within a period of 5 max. 30 sec. If the start time exceeds 35 sec., check that the discharge pipe is not
crushed or blocked.
After this operation the toilet can be used just like an ordinary one.
5.

MAINTENANCE AND CLEANING

Repairs to the motor or the electric components may be carried out only by
specialised and authorised personnel.
All repair and maintenance work must be carried out only after having disconnected
the appliance from the power supply mains.
In most cases any malfunctions are due to minimum causes which you can usually
solve yourself. For all other problems apply to an authorised repair centre (follow the
instructions in the TROUBLESHOOTING table).
5.1

Removing the grinder from the toilet pan

Disconnect the appliance from the power supply mains.
Turn off the corner supply tap and remove most of the water from the siphon of the toilet basin.
Disconnect the delivery pipe and the supply pipes.
Remove the appliance from the toilet.
Turn the electric power back on only after having concluded reassembly of the system.
5.2

Foreign bodies

If a foreign body gets into the Fekalift through the toilet, the problem can be solved easily without having to
contact service personnel: first of all take the plug out of the socket; remove the foreign body from the
toilet inlet with the aid of a screwdriver or a piece of wire. Take care not to make a hole in the pump inlet!
The blades are very sharp, NEVER PUT YOUR HAND INTO THE APPLIANCE!
ENGLISH
7

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Fekalift 200-aFekalift 300-a

Inhaltsverzeichnis