Herunterladen Inhalt Inhalt Diese Seite drucken

Connecting The Inverter; Connecting The Remote Control; Using The Inverter - Dometic DSP612 Montage- Und Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für DSP612:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 22
SinePower
8.2

Connecting the inverter

A
NOTICE!
• Make sure that you do not reverse the polarity. Incorrect polarity can
damage the inverter.
• Make sure that the inverter is operated with the following voltage
only:
– DSP612, DSP1012, DSP1512, DSP2012: 12 Vg
– DSP624, DSP1024, DSP1524, DSP2024: 24 Vg
I
NOTE
Tighten the nuts and bolts to a maximum torque of 15 Nm. Loose
connections may cause overheating.
➤ Connect the inverter as shown:
– Connecting the battery: fig. 7
– Connecting the ground terminal fig. 8
– Connecting the 230 V output cable: fig. 9
8.3

Connecting the remote control

A
NOTICE!
Only plug in the connection to the remote control in the remote port.
The device can be damaged by connecting it incorrectly.
➤ Connect the remote control as shown(fig. 0).
9

Using the inverter

9.1
Switching on the inverter
➤ Set the main switch (fig. 2 1) of the inverter as follows.
– "0": Inverter completely switched off
– "I": Standard operation
– "II": Operation via remote control
✓ The inverter performs a self-test.
EN
Using the inverter
13