Herunterladen Inhalt Inhalt Diese Seite drucken

Mounting The Inverter; Connecting The Inverter; General Instructions - Dometic ENERGY & LIGHTING MSI924M Montage- Und Bedienungsanleitung

Sinus-wechselrichter
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 24

Connecting the inverter

8.3

Mounting the inverter

➤ Hold the inverter against the installation location and mark the fastening points
(fig. 3 A, page 3).
➤ Attach the inverter using your chosen fastening method (fig. 3 B, page 3).
9
Connecting the inverter
9.1

General instructions

!
WARNING!
• The inverter may only be connected by a qualified workshop. The
following information is intended for technicians who are familiar
with the guidelines and safety precautions to be applied.
• Never use the inverter on vehicles where the positive terminal of the
battery is connected to the chassis.
• If you do not fit a fuse to the positive cable, the cables can over-
load, which might result in a fire.
• Reversed polarity can damage the inverter.
• The inverter should not be used to connect to a ring main, it must
only be used to power individual appliances that are plugged into
the inverter outlet either directly or using a purpose-made, moulded
extension lead
• When setting up a socket distribution circuit (mains setup), comply with the
applicable regulations.
• Only use copper cables.
• Keep the cables as short as possible (< 1.8 m).
• Keep to the specified cable cross section and fit a cable fuse (fig. 6 3, page 5)
as close to the battery as possible on the positive cable (see the table).
Device
MSI924M
14
Required cable
cross section
≤ 10 mm²
MSI924M
Cable fuse
(fig. 6 3, page 5)
50 A