Herunterladen Inhalt Inhalt Diese Seite drucken

Dometic DSP612 Montage- Und Bedienungsanleitung Seite 17

Vorschau ausblenden Andere Handbücher für DSP612:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 22
SinePower
9.3
Switching to energy-saving mode
I
NOTE
The inverter automatically switches to normal mode when a load with
more than 45 W is connected.
➤ With the inverter off, push the remote control's on/off button (fig. 3 1) for 5 s to
activate or deactivate the save mode.
✓ The remote control's status LED (fig. 3 2) flashes six times.
✓ After that, the remote control's status LED (fig. 3 2) indicates the operation
mode:
– Constantly lit: Normal mode activated
– Flashes: Energy-saving mode activated
9.4
Configuring the net configuration
D
DANGER!
Changing the net configuration results in risk of lethal injury.
The dip switch must only be set by qualified personnel.
Remove the the dip switch's protection cap for configuring only. Insert
the protection cap to prevent switching the dip switch's setting.
Using the dip switch you can define in which net configuration the inverter shall
operate.
Parameter
An external downstream circuit breaker (RCD) is
necessary.
Operation with one load only or installation of an
external insulation monitor.
National standards shall apply!
EN
TN grid
IT grid
Using the inverter
Dip switch
On
Off
15

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis