A U T O S T A R T F U N C T I O N
Filling Procedure Semi-Automatic Operation
Caution! Only fill cylinders which:
i
- are marked with the test mark and the test stamp of the expert.
- have been hydro static tested (check last test date).
- are rated for the final pressure.
- are free from humidity.
Note
i
The unit shuts down when final pressure is reached. Thus, the unit always has to be
restarted manually.
1.
Turn selector switch to semi-automatic mode.
2.
Close all filling valves.
3.
Connect closed compressed air cylinders.
4.
Open cylinder valves.
5.
Start compressor by pushing the ON button.
6.
If the filling pressure increases, open the filling valves slowly.
7.
Fill compressed air cylinders to the desired pressure, subsequently close filling valves slowly.
8.
Close and vent all filling valves.
9.
Disconnect all compressed air cylinders from filling valves.
Version: 10.05.2017
LW 570 E II Compact
D
C - 10