4. VIDEO SIGNAL PRESENCE TEST
The apartment stations are provided with a yellow LED which indicates possible system anomalies.
The yellow LED will be switched on in the event of the following anomalies:
• Wrong line terminal confi guration (z) on devices.
• Distributors without jumper.
• Distribution branches without terminals.
• Master door unit either not connected or not working.
5. BASIC FUNCTIONAL TEST
For this test, call the user, test the ringer, check for presence of the image, test for voice and lock release.
• Press a calling button on the Master calling station.
• User's extension 0 must switch the monitor on. The user has 60 seconds to switch the audio on (
button).
• The monitor of indoor stations 1, 2, 3 cannot be switched on if there several indoor stations are connected
in parallel. Press the auto-on button (button
("video switching" function). This operation can be repeated on all called user's monitors until the 60
second call timeout or until one of the audio buttons of one of the video door phones defi nitively picks up
the picture.
• A conversation which can last for up to 2 minutes will be established when the audio is activated.
• The electrical lock can be operated by pressing the specifi c button from the time of the call to the end of
the conversation.
• Press the
button again to switch all the system to stand-by.
6. OPTIONAL PROGRAMMING FOR ADDITIONAL FUNCTIONS
The following programming operations are needed after testing the basic operation of the system only if the
following functions are required:
1. Free door lock release function: set the appropriate dip switch to activate the function.
2. Surveillance camera auto-on function: set the appropriate dip switch to activate the function.
3. Indoor station intercom function: associate the user code to be called or the apartment code to be called
to the buttons.
4. Door phone tone: select one of the fi ve options.
5. Floor call tone: select one of the fi ve options.
DOOR UNIT FREE DOOR
OPENER FUNCTION
FREE
PRIVACY
(default)
1 2
1 2
22
Yellow Led
ON
DIP
ON
1 2 3 4 5
1 2
) to switch on the monitor of another video door phone
SURVEILLANCE CAMERAS
AUTO-ON FUNCTION
OFF
ON
(default)
1 2
1 2
INDOOR STATION INTERCOM FUNCTION
1. Go to the indoor station to be programmed as caller (indoor station C1).
2. Hold the door opener button pressed and press the
unit will generate a tone to indicate access to button programming mode.
3. Press the button to be programmed. The indoor station will output a confi rmation tone. The button can
be
or
or
4. Go to the indoor station that the button will call (apartment station C2) and press the door opener button.
The indoor stations C1 and C2 will be beep to indicate that they have been programmed.
5. Press the
button of the C1 apartment station (the blue LED will go out). A beep indicating that
programming mode is shut down will be issued.
6. Check the programmed function: press the
programming button.
Check that the indoor station C2 rings and check audio.
DS1782-004A
DS1782-004A
button (the blue LED will light up). The C1 door
C1
2
..
C1
3
C2
4
button of the C1 apartment station and press the
1