TYPES OF WIRES USED
The two-wire bus is NOT polarised. Only use the wire of the type shown in the following table according to
the distance and the type of indoor stations used. Use the dedicated wire Ref. 1082/90 for optimal system
performance.
E
Type of wire
Ref. 1082/90 wire
Max. n. of door units
Max. n. of columns
Max. n. of apartment stations
Max. n.
of single user distributors
Max. distance between
apartment station and power unit (A)
Max. distance between power unit
and apartment station (B)
Max. distance between
apartment station and power unit (C)
Max. distance
between apartment stations (D)
Max. extension
of the system
(*) Use of a twisted wire is recommended to improve system effi ciency and increase interference immunity.
The common segments running in the same connection tube to the riser column and the video door phone
must be considered when calculating the maximum distance and must be max. 2m each if wires without
sheath are used.
18
D
B
C
A
TC
Urmet Domus
Twisted telephone
wire Ø 0.6
min. sec. 0.5mm
not category 5
max. sec.1.5mm
1
1
1
1
4
4
3
0
75m
75m
75m
50m
150m
75m
150m
75m
375m
75m
≤ 2m
ELECTRICAL LOCK CONNECTION
Type of wire
Max. distance between
door unit
and electrical lock (E)
DOOR UNIT AUXILIARY SIGNAL CONNECTION
Type of wire
Max. hall button
distance
(PA-GND)
Max. surveillance
cameras switching
signal distance
WIRING AND USE OF LINE TERMINALS
Other wires (∗)
DEFINITIONS
2
SPINE
2
1
EXTENSION
1
END OF LINE
4
TERMINATION (Z)
0
CONNECTION IN-OUT
75m
The 2GO! system elements must be interconnected in a genuine transmission network. For this reason, each
75m
network section must be adapted to the wire impedance for correct operation. Consider the following:
• Only use the type of wire shown in the previous chapter.
75m
• The minimum twisting radius must not be less than 10 times the external diameter of the wire
(approximately 7cm) to prevent altering characteristics.
• Remove the sheath for the length needed to separate the pair in the two-wire line only.
75m
• Do not add electrical nodes to connect the devices. Use the device terminals only. Fit a Ref. 1082/51
video distributor to connect an extension indoor unit to a riser column that does not cross the apartment:
75m
DS1782-004A
DS1782-004A
2
2
Wire 0,28mm
Wire 0,5mm
Wire 1mm
30m
50m
2
2
Wire 0,28mm
Wire 0,5mm
Wire 1mm
25m
25m
75m
75m
Two-wire line leading from a terminal pair of the power unit to which
the devices are connected
Two-wire line leading from "DER" terminals of the distributor to which
the devices are connected
The last device connected to a spine or extension
Impedance to be fitted at the end of each line by means of a switch
to adapt a spine or an extension
Connection of devices using the "LINE" terminals as nodes in pair
and out pair
NO
OK
IN/OUT DER
2
100m
2
25m
75m
19