• This completes the general commissioning of the projection radio alarm clock.
You can operate the projection radio alarm clock without the plug-in mains
adapter this way. However, the display will only be lit and the projection
switched on when the button "SNOOZE/LIGHT" (B5) is pushed. This lasts
about 5 seconds.
c) Connecting a plug-in mains adapter
After the power adapter is attached the display is lit permanently and perma-
nent projection is achieved.
When acquiring a plug-in mains adapter, pay attention to the technical data. It must
provide an output voltage of 4.5 V/DC at 200 mA. The output plug must have an outer
diameter of 3.5 mm and an inner diameter of 1.5 mm.
• Connect the output of the plug-in mains adapter to the intended socket B12 at the rear
of the projection radio alarm clock.
• Now plug the mains adapter into a mains socket.
Both permanent display illumination and permanent projection are now ena-
bled.
• To enable permanent projection, slide the switch B9 on the back to position "ON" (to
the left).
• To enable permanent display illumination, slide the switch B10 on the back to position
"ON" (to the left).
• When one of the two functions is deactivated, it can still be activated for 5 seconds
with the button "SNOOZE / LIGHT" (B5).