Mounting
The PKM 05 can be mounted on either the left or right
side of FIGHTER 1240 (see figure).
The supplied bracket is screwed into the holes drilled ac-
cording to the enclosed hole drilling template, or accor-
ding to the dimensional drawing below.
NOTE! Drill with caution through the plate to avoid da-
mage to vessels or other equipment.
When mounting on a wall, use the supplied mounting
bracket, which should first be mounted on the wall with
screws (use the enclosed hole drilling template).
NOTE! Adapt the drilling of the holes, mounting and
placement on the wall to the type of wall and other re-
levant conditions of the site.
Then mount the cooling module on the bracket. The
cooling module can now be slid sideways to some ex-
tent, which facilitates the fitting of the pipes.
260
100
4x Ø4,5
LEFT
Left
NOTE!
The factory setting of the mixing valve is
cooling mode.
10
100
260
4x Ø4,5
Right
RIGHT
Support sleeve ø28
PKM 05

Pipe connections

Pipes for connecting to and assembling the FIGHTER
1240 are supplied in the kit.
The pipes are connected as described below (see figure
below and schematic diagram):
(B) connects to the heating medium return on the
heat pump. If the PKM 05 is mounted on the right-
hand side of the heat pump, adjust the length of
the pipe.
(D) connects to the brine in to the heat pump.
(A) connects to the return from the heating me-
dium system.
(C) connects to the inlet from the collector.
Support sleeve ø22
Left

Component positions

E
C
D
A Heating medium return (to PKM)
B
Heating medium return (from PKM)
C Brine in (to PKM)
D Brine out (from PKM)
E
Mixing valve
FIGHTER 1240
Right
B
A