Continuity check

Be sure to remove the parts from AC Mains or high vol-
tage! While checking, press the switch (4) and put the
Test-PIN (7) in contact with one side of the object, and
be sure that the free hand touches the other side ot the
object too.
Continuity indicating by LED (2) blinks and buzzer
sounds.
Maintenance, care and Disposal
Use a soft, lint-free, anti-static cloth only to clean the device from
the outside. By no means use any scouring agent or solvent. Main-
tenance or repair may be carried out by a specialist only who is
acquainted with the pertinent regulations (VDE-100, VDE-0701).
Once the product becomes unusable, dispose it in accordance with
the relevant statutory regulations.

Technical data

Range of testing voltage
Frequency range
Voltage supply
Dimensions
Weight
Ambient conditions
Working temperature range
Relative humidity:
18
: 70 VAC to 440 VAC
: 50 Hz to 500 Hz
: 3 VDC (2 x round cells LR44)
: (W x L x D) 22 x 142 x 25 mm
: 34 g (including batteries)
: -10° to +50° Celsius (14° to 122° F)
: < 90% (non-condensing)
Introduction
Dear Customer,
Thank you very much for purchasing the Multitester MS-258 II.
With this device, you have purchased a product designed in accor-
dance with the latest state of the art.
In order to maintain this status and to ensure safe operation, you as
the user have to comply with these operating instructions.
For a fast response of your technical enquiries please use
the email address listed below.
Germany:
Fon.
Fax
e-mail: tkb@conrad.de
Mon to Thurs 8.00am to 4.30pm
Fri

Intended Use

The intended use comprises the non-contact detection of alternat-
ing current with optical and acoustic indication on electric wires,
cables, sockets, switches, et cetera of 70 to 440 VAC as well as the
detection of metal parts, such as wires, cables, screws, nails et
cetera in walls, ceilings, et cetera and Coutinuity check. Two round
cells of type LR44 (1.5 VDC) or a similar type only may be used for
power supply. The operation is permitted in dry and closed rooms
only; the contact with moisture has to be avoided without fail.
+ 49 9604/40 88 80
+ 49 9604/40 88 48
8.00am to 2.00pm