Technical data

Determined on the basis of EN 14511 or Truma test conditions
Designation
Saphir compact, comfort air conditioning system
Dimensions (L x W x H)
560 x 400 x 290 mm
Weight
20 kg
Power supply
230 V – 240 V ~, 50 Hz
Maximum cooling power
1800 W
Starting current
15 A (150 ms)
Power consumption
2.8 A / 35 °C
Protection class:
IP X5 (when installed)
Volume flow (cold air)
max. 310 m³/h
Refrigerant
R 407C / 0.39 kg
Contains fluorinated greenhouse gases covered by the Kyoto
Protocol. Hermetically sealed.
Global warming potential (GWP)
1774
CO2 equivalent
691.9 kg
Maximum incline of vehicle during
operation
8 %
Usage limits
+16 °C to +40 °C.
– An interior air sensor prevents the compressor from operat-
ing at temperatures of less than +16 °C.
– An anti-freeze sensor prevents non-permitted ice formation
on the evaporator coil.
– A temperature switch prevents excessive current and tem-
perature at the compressor.
E24 10R-040991
Right reserved to make technical changes!
20

Function diagram

Supply air
intake from
Compressor
the outside
Condenser
Fan
Supply air
Throttle
outlet to the
outside-downwards
High-pressure side
Fig. 12

Installation dimensions

The dimensions are in mm.
281
KO
60
Saphir compact
Fig. 13
Cold air
outlet
Circulated
air intake
from inside
Low-pressure side
560
195
LA
84
LE
63
15