Herunterladen Inhalt Inhalt Diese Seite drucken

Küppersbusch IKEF3082Z3 Benutzerinformation Seite 35

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Problem
The compressor does not
start immediately after press-
ing the FastFreeze, or after
changing the temperature.
The compressor does not
start immediately after press-
ing the Intensive cooling, or
after changing the tempera-
ture.
Water flows on the rear plate
of the refrigerator.
Water flows into the refrigera-
tor.
Water flows on the floor.
Temperature cannot be set.
DEMO appears on the dis-
play.
Door is misaligned or inter-
feres with ventilation grill.
The temperature in the appli-
ance is too low/too high.
Possible cause
Temperature is set incorrect-
ly.
This is normal, no error has
occurred.
This is normal, no error has
occurred.
During the automatic defrost-
ing process, frost melts on
the rear plate.
The water outlet is clogged.
Food products prevent that
water flows into the water
collector.
The melting water outlet is
not connected to the evapo-
rative tray above the com-
pressor.
The FastFreeze or Intensive
cooling function is switched
on.
The appliance is in demon-
stration mode.
The appliance is not levelled.
The temperature regulator is
not set correctly.
The door is not closed cor-
rectly.
Solution
Refer to "Operation" chapter.
The compressor starts after a
period of time.
The compressor starts after a
period of time.
This is correct.
Clean the water outlet.
Make sure that food prod-
ucts do not touch the rear
plate.
Attach the melting water out-
let to the evaporative tray.
Switch off FastFreeze or In-
tensive cooling manually, or
wait until the function resets
automatically to set the tem-
perature. Refer to "Fast-
Freeze or Intensive cooling
function".
Keep the OK pressed for ap-
proximately 10 seconds until
a long sound is heard and
display shuts off for a short
time.
Refer to "Levelling".
Set a higher/lower tempera-
ture.
Refer to "Closing the door".
35

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis