34
Problem
A square symbol is shown in-
stead of numbers on the
Temperature Display.
The lamp does not work.
The lamp does not work.
The compressor operates
continually.
There is too much frost and
ice.
Possible cause
The temperature in the appli-
ance is too high.
The door is left open.
The temperature in the appli-
ance is too high.
Temperature sensor prob-
lem.
The lamp is in stand-by.
The lamp is defective.
Temperature is set incorrect-
ly.
Many food products to be
frozen were put in at the
same time.
The room temperature is too
high.
Food products placed in the
appliance were too warm.
The door is not closed cor-
rectly.
The FastFreeze function is
switched on.
The Intensive cooling function
is switched on.
The door is not closed cor-
rectly or the gasket is de-
formed/dirty.
The water drainage plug is
not correctly positioned.
Food products are not wrap-
ped properly.
Solution
Refer to "Door Open
Alarm"or "High Temperature
Alarm".
Close the door.
Contact a qualified electrician
or contact the nearest Au-
thorized Service Centre.
Contact the nearest Author-
ized Service Centre (the cool-
ing system will continue to
keep food products cold, but
temperature adjustment will
not be possible).
Close and open the door.
Contact the nearest Author-
ized Service Centre.
Refer to "Operation" chapter.
Wait some hours and then
check the temperature again.
Refer to climate class chart
on the rating plate.
Allow food products to cool
to room temperature before
storing.
Refer to "Closing the door".
Refer to "FastFreeze func-
tion".
Refer to "Intensive cooling
function".
Refer to "Closing the door".
Position the water drainage
plug in the correct way.
Wrap the food products bet-
ter.