10. TROUBLEShOOTING

With this meter, you purchased a product built to the state of the art and operationally safe.
Nevertheless, problems or errors may occur.
For this reason, the following is a description of how you can easily remove possible malfunctions yourself:
Always observe the safety information!
Error
The meter does not work.
The connected voltage
meter does not display
any measured values.
Repairs other than those described above should only be carried out by an authorised specialist.
If you have any questions about handling the meter, our technical support is available.
Possible cause
Are the batteries dead?
The meter is off.
Is the wrong measuring function acti-
vated at the voltage meter (DC)?
Is direct current measured?
Are the measuring lines reliably inserted
in the measuring jacks?
Is the hold function at the voltage meter
activated?
Was a matching measuring range
chosen at the voltage meter or is the
resolution sufficient for the output
voltage.
Is the measuring range of the Flex cur-
rent probe chosen incorrectly (too small/
too large)?
Remedy
Check the status. Replace the battery.
Push the operating switch (2).
Check the measuring function (AC) and
switch the function if required.
The Flex current probe can only measure
alternate current.
Check the proper fit of the measuring lines
Push the button "HOLD" to deactivate this
function.
Check the measuring range.
Check the measuring range.