Installation
INSTALLATION
The versatility of the ducting fan unit on this hood enables it to be installed in one of two
different ways:
1 - Air outlet directed towards the wall.
2 - Air outlet directed to the right or left.
For correct installation of the hood, please proceed in the following stages:
4.1 - Selection of the type of installation
4.2 - Installation of the hood canopy C
4.3 - Installation of the chimney A
4.4 - Ducting or recirculation fitting
4.5 - Electrical connection and testing
Selecting the type of installation
1 - Air discharge towards the wall (fig.2)
2-Side air discharge, Left or Right (fig.3a-b).
Installation of the hood canopy C
1 - Drilling the wall
a) Using the cardboard template
provided, mark on the wall the
centres of holes 1 for fixing of the
hood canopy C. The centre of hole 2
for fixing the chimney, (fig.4a) air
outlet towards the wall, (fig. 4b-c) air
outlet to the right or left hand side,
must be marked at a distance X from
the line between holes 1, obtained
by measuring the extension of the
chimney required for installation, plus
13 mm X=Z+20-7. Using a Ø 8 mm
drill bit, drill the points marked in this
way.
b) When installed with the air outlet
directed towards the wall (fig.4a), it
will be necessary to drill an air
ducting opening, measuring Ø120 or 125 mm, according to the diameter of the flange F
provided.
44
S07_04
3a
4a
2
A08_05
R
2
1
1
1
ø 8
100 100
4a
R
3b
4b
105
105
2
2
1
1
4b
4c
1