Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting - Scheppach Bsg1200Max Original Bedienungsanleitung

Vorschau anzeigen Andere Handbücher für BSG1200MAX:
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

  • DEUTSCH, seite 1
- Public disposal or collection points (e.g. municipal
works yards)
- Sales points for batteries and rechargeable bat-
teries
- Take-back points of the common take-back sys-
tem for old device batteries
- Take-back point of the manufacturer (if not a
member of the common take-back system)
• These statements are only valid for rechargeable
batteries and batteries sold in the countries of the
European Union and subject to the European Direc-
tive 2006/66/EC. Different provisions can apply to
the disposal of rechargeable batteries and batteries
in countries outside the European Union.

17. Troubleshooting

The following table shows fault symptoms and describes remedial measures in the event of your product failing to
work properly. If you cannot localise and rectify the problem with this, please contact your service workshop.
Fault
Possible cause
Overheating protection
Battery over-current pro-
tection
Battery charging protection
Protection at low discharge
temperatures
Battery low voltage pro-
tection
Device does not
work or not as
Power inverter overcurrent
expected
protection
Power inverter overload
protection
Power inverter short-circuit
protection
Protection against overvolt-
age while charging
Battery overheat protection
30 | GB
Removing the battery before disposing of the de-
vice
• The integrated battery must be removed and dis-
posed of separately in an environmentally friendly
manner before disposing of the device.
• Mask off the contacts and package the battery such
that it cannot move in the packaging. Please also
observe any further national regulations.
Remedy
Check the ambient temperature. Output is restarted when
the generator cools down.
Disconnect the product from the power connection and carry
out commissioning again.
Contact the customer service department.
Check the ambient temperature to see if it is lower than
-10°C.
Charge the product in good time, restart after it has fully
charged.
Check if the AC output is overloaded or short-circuited.
Check if the AC output is overloaded.
Check if the AC output is overloaded or short-circuited.
Check whether the input voltage exceeds the maximum input
voltage.
Check if the ambient temperature is higher than 45°C.
Allow the product to cool down.