OPERATION

Operation of the fog machine is via the cable remote control provided or via DMX.

Switching on and off

1
Switch on the machine with the power switch. The switch lights up. The fog machine
will heat up for approx. 10 minutes. While the unit is warming up, fog output will not
be possible yet.
2
Once the warm-up process is completed, the green control indicator on the remote
control will light up. The fog machine is now ready to emit fog and can be controlled
with the remote control or via DMX.
3
After operation, switch off the machine with the power switch.
The output nozzle will heat up during operation. Therefore do not touch the nozzle until it has
cooled down completely!
Prior to transportation, allow the machine to cool down and completely empty the tank.
Never operate the fog machine without fog fluid. Fire hazard due to overheating! Besides, the
unit may be damaged.
During operation smoke emission may stop. In this case the device is heating up again. After
a short period, the machine will be ready to emit fog again. This process guarantees an
appropriate vaporization temperature and the best fog emission possible. The temperature is
regulated by a high-quality thermostat.

Manual Fog Output

To manually activate a fog output, press the green MANUAL button on the remote control.
While this button is kept pressed, the unit will emit the maximum amount of fog.
The manual mode will take priority over the continuous and timer mode, i.e. when the green
button is pressed, the unit will always emit the maximum amount of fog even if one of the
other modes is activated.

Continuous Mode

In the continuous mode, the fog machine will emit fog continuously. The output volume is
adjustable.
1
To activate the continuous mode, press the red button CONTINOUS, so that it will
engage and the control indicator above the button lights up.
2
With the control OUTPUT, adjust the fog output volume between 0 and 100 %.
3
To deactivate the continuous mode, disengage the red button CONTINOUS again.
The red control indicator above it will be extinguished.
The continuous mode will take priority over the timer mode, i.e. when the red button is
pressed, the unit is set to continuous mode even if the timer mode is activated with the
button timer.