Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Before Starting The Equipment - EINHELL 34.036.72 Originalbetriebsanleitung

Vorschau ausblenden Andere Handbücher für 34.036.72:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Anleitung_RG_EH_7160_SPK1:_

5. Technical data

Voltage
Power consumption
Cutting length
Cutter rail length
Tooth spacing
max. cutting ø
Cuts/min
Sound power level L
WA
Sound pressure level L
pA
K uncertainty
Vibration a hv
K uncertainty
Weight
Idling speed:
Sound and vibration
Sound and vibration values were measured in
accordance with EN 60745-1; EN 60745-2-15; EN
2000/14/EC.
Wear ear-muffs.
The impact of noise can cause damage to hearing.
Warning!
The specified vibration value was established in
accordance with a standardized testing method. It
may change according to how the electric equipment
is used and may exceed the specified value in
exceptional circumstances.
The specified vibration value can be used to compare
the equipment with other electric power tools.
The specified vibration value can be used for initial
assessment of a harmful effect.
Keep the noise emissions and vibrations to a
minimum.
Only use appliances which are in perfect working
order.
Service and clean the appliance regularly.
Adapt your working style to suit the appliance.
Do not overload the appliance.
Have the appliance serviced whenever
07.03.2012
7:47 Uhr
necessary.
Switch the appliance off when it is not in use.
Wear protective gloves.
230-240 V ~ 50Hz
Residual risks
710 W
Even if you use this electric power tool in
600 mm
accordance with instructions, certain residual
risks cannot be rules out. The following hazards
660 mm
may arise in connection with the equipment's
24 mm
construction and layout:
20 mm
1. Lung damage if no suitable protective dust mask
is used.
3200/min
2. Damage to hearing if no suitable ear protection is
98 dB
used.
3. Health damage caused by hand-arm vibrations if
89,7 dB
the equipment is used over a prolonged period or
3 dB(A)
is not properly guided and maintained.
front handle 6,145 m/s
2
rear handle 3,608 m/s
Warning! This electric power tool generates an
1,5 m/s
2
electromagnetic field during operation. Under certain
circumstances this field may actively or passively
4,1 kg
impede medical implants. To reduce the risk of
1600 min
-1
serious or fatal injuries, we recommend persons with
medical implants to consult their doctor and the
manufacturer of the medical implant prior to using the
equipment.

6. Before starting the equipment

Before you connect the equipment to the mains
supply make sure that the data on the rating plate
are identical to the mains data.
b
Rotary rear handle (Figures 2-4)
The hedge shears are fitted with a rear rotary
handle. This can be turned counter-clockwise
through 90° and clockwise through both 90° and
180°. For this purpose the top slide (Fig. 2/Pos.
1) must be pushed backwards in the direction
indicated by the arrow. Then pull the slide (E) in
the direction indicated by the arrow and turn the
handle. If you turn it counter-clockwise the
handle will lock at an angle of 90° (Fig. 3). If you
turn it clockwise the handle will lock at an angle
of 90° and 180° (Figure 4). Pull the slide (E) in
the direction indicated by the arrow again to
return the handle to its original position. When
the handle is back in its standard position the top
slide (E) must be pushed forward to lock it.
For vertical cutting the handle should be set to
90° and for overhead cutting it should be set to
180°.
Seite 11
GB
11

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Rg-eh 7160

Inhaltsverzeichnis