Operating Instructions SATAjet 100 B F RP/HVLP, B P
EN
Malfunction
Round/flat spray con-
trol cannot be regu-
lated
Spray gun does not
shut-off air
Corrosion on air cap
thread, inside material
passages (cup con-
nection) or on spray
gun body
Material leaks from
behind the paint nee-
dle sealing.
Spray gun leaks from
the fluid tip ("fluid tip
aperture").
11. Disposal
Recycle the completely empty spray gun. To protect the environment, bat-
teries and residual paint have to be disposed in an appropriate way and
separately from the spray gun. Please observe local legislation!
112
Cause
Control has been
turned in counterclock-
wise direction into the
limitation; spindle has
loosend inside the
spray gun thread
Clogged air piston seat
or worn air piston.
Cleaning solution
(water-based) remains
inside/on the spray
gun for too long.
Unsuitable cleaning
solutions
Defective or missing
paint needle sealing.
Clogged or damaged
paint needle.
Contamination be-
tween paint needle tip
and fluid tip.
Damaged nozzle set.
Corrective Action
Remove control with
universal spanner;
rectify or replace com-
pletely, chapter 9.6
Clean air piston seat
and/or replace air pis-
ton, air piston packing,
chapter 9.4
Cleaning, observe
chapter 8, get a
replacement spray
gun body.
Replace / insert paint
needle sealing, chap-
ter 9.3.
Replace nozzle set,
chapter 9.1; replace
paint needle sealing,
if necessary, chapter
9.3.
Clean fluid tip and
paint needle, observe
chapter 8.
Replace nozzle set,
chapter 9.