Operating Instructions SATAjet 100 B F RP/HVLP, B P
6.4. Use in explosive areas
Ex-sign
Equipment cat-
egory
6.4.1 General
The paint spray gun is approved for the use / storage in explosive areas
of Ex-Zone 1 and 2.
• The following applications and operations lead to the loss
of the explosion protection and are, therefore, prohibited:
• Use of the paint spray gun in explosive areas belonging to ex-zone 0!
• Do not use solvents and cleaning agents based on halogenised
hydrocarbons! Chemical reaction which may occur when using these
substances may be explosive!
7.
Use
• Use only solvent-resistant, antistatic, undamaged and technically
flawless compressed air hoses with a permanent pressure resistance
of minimum 10 bar (145 psi), e.g. Art. No. 53090!
The following requirements must be fulfilled:
• Use a compressed air connection G 1/4 a or a fitting SATA connection
nipple.
• Ensure minimum compressed air volume (air consumption) and pres-
sure (recommended spray gun inlet pressure) according to chapter 2.
Device category
Warning! Risk of explosion!
Warning! Risk of explosion!
Note!
Gas category
Temperature level
EN
105