Herunterladen Diese Seite drucken

EuroLite RDL-70 Benutzerhandbuch Seite 13

Verfügbare Sprachen

Verfügbare Sprachen

This device must only be operated in an altitude between -20 and 2000 m over NN.
- - -m
The symbol
between light-output and the illuminated surface must be more than 1 meter.
This device is only allowed for an installation via the mounting bracket. In order to safeguard sufficient
ventilation, leave 50 cm of free space around the device.
The housing must never touch surrounding surfaces or objects.
Make sure that the area below the installation place is blocked when rigging, derigging or servicing the
fixture.
The maximum ambient temperature T
Operate the device only after having familiarized with its functions. Do not permit operation by persons not
qualified for operating the device. Most damages are the result of unprofessional operation!
Never use solvents or aggressive detergents in order to clean the device! Rather use a soft and damp cloth.
Please use the original packaging if the device is to be transported. Make sure that you pack the device in
the original state.
Please consider that unauthorized modifications on the device are forbidden due to safety reasons!
If this device will be operated in any way different to the one described in this manual, the product may suffer
damages and the guarantee becomes void. Furthermore, any other operation may lead to dangers like short-
circuit, burns, electric shock, lamp explosion, crash etc.
INSTALLATION
Installing/Replacing the lamp
For the installation, you need one HQI 70W or HQI 150W R7s 117mm pole-burner or one 100W R7s 117mm
pole-burner or one CDM 70W or CDM 150W G12 lamp.
The lamp must only be changed when wearing appropriate protective clothing (protection glasses, protection
gloves, helmet with sight, leather apron).
The lamp life given by the manufacturer must never be exceeded. This is why you need to take notes on the
operational time of the lamp or check the operating hour meter regularly and replace the lamp in time.
Keep exchanged lamp in a protective container and remove accordingly.
During the operation, the lamp reaches temperatures of up to 600° C.
Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 10 minutes).
determines the minimum distance from lighted objects. The minimum distance
= 45° C must never be exceeded.
a
The lamp has to be replaced when it is damaged
or deformed due to the heat!
CAUTION!
13/17
50808200_V_1_0.DOC