Note
All cables must be protected from heat. Improper installation can damage
your stove and void your warranty.
Run the cables further through the two recesses at the heat deflectors.
Run the cables between the here shown transparent supply air duct and the
conveyor trough back to the green marked vertical cable duct.
Loosen the nut and the ring from the capacitor till the end from the thread.
Attach the condenser (with 2 blowers both capacitors) in the free slots behind
the cable channel.
In the cable channel are the three pin connector M3 for the upper convection
fan 1 and the plug M4 for the lower convection fan 2. Insert the correct cable
and put all cables and plugs back into the cable channel.
Install the rear wall of the stove. It is mandatory to attach the motor cover on
the rear wall.
Note
Operation without a motor cover and without air duct is not allowed for
security reasons. Disregard voids your warranty and no liability is accepted
for damage.
Function test and settings
Connect the power cord back in and select the Setup menu /submenu
Service. Perform a relais test to check the correct function of the Multi Air fan.
Select
the
Setup
MultiAir 1 to ON and you will get access to fan speed and fan adaptation.
Fan level
The volume of convection air is adjustable from AUTO (adapts automatically
according to heating power), over to Level 1 (min) and level 5 (max).
Fan area
In addition, it is possible to adapt the Multi Air fan speed (AUTO, level 1 to level
5) within +/- 30% of fan speed.
#13
#13
menu
/submenu
MultiAir
fan.
Switch
the