RIKA Interno Montageanleitung Seite 14

Option für raumluftunabhängigen betrieb
Vorschau ausblenden Andere Handbücher für Interno:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Delivered Parts E 15621
1x B17498
Q
air intake adapter
Dimensions
Variante I
Dimensions
H - height
B - width
T - corpus depth
Mounting dimensions
H - E height (min.)
B - E width (min.)
T - E corpus depth (min.)
Weight
Weight of the stove
Weight of the base plate for mounting
Flue pipe connection
R - Ø flue pipe outlet
RO - H original angle pipe connection height
RO - T1 original angle pipe total depth
RO - T2 original angle pipe distance to rear wall
RO - T3 deapth from rear wall to middle of flue
pipe
RO - S original angle pipe side distance
R - H rear connection height
R - S rear connection side distance
Fresh air connection
F - Ø diameter
F - H connection height
F - S side distance
F - T connection depth
Variante II
[mm]
617/686
[mm]
790/920
[mm]
580
[mm]
560
[mm]
690
[mm]
510
[kg]
141
[kg]
30
[mm]
100
[cm]
26
[cm]
7
[cm]
-
[cm]
-
[cm]
11
[cm]
17
[cm]
11
[mm]
50
[cm]
14
[cm]
30
[cm]
6
1x B17497 air intake pipe
Q
1x N111293 hose clamp
Q
4x N108313 hex screws
Q
Explanations to symbols
...Allen key #2
#2
...Hex #7
# 7
...manually
Important Information
Note
Read the entire manual thoroughly before installing and putting the stove into
service. Observe the national provisions and laws as well as the regulations
and rules applicable locally.
Note
Only work on the unit when the mains plug has been disconnected. Your stove
must be switched off and cooled.
Combustion air must be fed to the stove from outside via a sealed pipe
Q
for operation independent of the room air. According to EnEV, it must be
possible to shut off the combustion air pipe. The open/closed setting must
be clearly recognisable.
Connect to the intake adapter a pipe with diameter Ø50mm and fix this
Q
with a pipe clamp (not included in scope of supply!). To ensure sufficient air
intake, the line should not be longer than 4m and should not have too many
bends.
If the line leads outside it must have a windbreak.
Q
In extreme cold pay attention to icing of the air intake opening (check).
Q
It is also possible to suction in combustion air directly from another
Q
sufficiently vented room (e.g. cellar).
The combustion air pipe must be tightly connected (adhesive or cement)
Q
permanently to the air nozzles of the stove.
If you do not use the stove for a long time, please close the combustion air
Q
intake to prevent the stove from moisture.
If one or more of these conditions does NOT apply, the result is poor combustion in the
stove and negative pressure in the installation room.
...Allen key #5
#5
...Hex #8
# 8