A water pump is necessary (Supplied by the user). The recommended pump specification:
2
refer to table 2.4-1.
When the device is running, condensation water will be discharged from the bottom, so
3
please pay attention to it. Please insert the drainage pipe (accessory) into the hole and clip it
well, then connect a pipe to drain the condensation water. The condensate drain outlet is at the
bottom of the device, and the condensate pipe must be lower than the condensate drain outlet.
3.3.3. Location and Space
Please comply with the following rules concerning the choice of device location.
The device's future location must be easily accessible for convenient operation and
1
maintenance.
It must be installed on the ground, fixed ideally on a level concrete floor. Ensure that the
2
floor is sufficiently stable and can support the weight of the device.
A water drainage device must be provided close to the device in order to protect the area
3
where it is installed.
If necessary, the device may be raised by using suitable mounting pads designed to support
4
its weight.
Check that the device is properly ventilated, that the air outlet is not facing the windows of
5
neighboring buildings and that the exhaust air cannot return. In addition, provide sufficient space
around the device for servicing and maintenance operations.
The device must not be installed in an area exposed to oil, flammable gases, corrosive
6
products, sulfur compounds or close to high frequency equipment.
To prevent mud splashes, do not install the device near a road or track.
7
Figure 3.3-2 Fixed Device
Table 3.3-2 Fixed Device
No.
Device Feet
①
Rubber Pad
②
Figure 3.3-3 Connection Instruction
20
Item