10
Behavior after power
restoration
After switching the operating voltage on (mains vol-
tage returned), the actuator checks the respective
components. If an error is detected during this test, it
is indicated by a flashing LED. This is repeated conti-
nually and the device starts to work with the respective
functionality.
If the test runs without any errors, the actuator sends a
radio telegram with the respective status information.
The actuator waits a random delay time before sen-
ding so that all actuators are not sending at the same
time when the power returns (after a power outage or
shut-down). During this time, the device LED flashes
(like in teach mode).
If the delay time is short, the flashing may not even be
noticeable.