Herunterladen Inhalt Inhalt Diese Seite drucken

WimTec OCEAN P7 Montage- Und Bedienungsanleitung Seite 29

6 v batteriebetrieb
Vorschau ausblenden Andere Handbücher für OCEAN P7:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

OCEAN P7
Program description
Cleaning stop:
DIP-switch 5
Serves to disable the fitting prior to cleaning.
Dip-switch 5 ON = Cleaning stop function enabled (default setting).
Dip-switch 5 OFF = Cleaning stop function disabled.
User detection
To activate the shower, the
user must enter the active
range.
30-70 cm
Enable cleaning stop
Approaching the hand to the
infrared sensor (see picture).
After 2 s the vertical line of the
ON/OFF icon begins flashing.
At the same time tap with the
second hand inside the ON/
OFF icon and the cleaning stop
is enabled.
The cleaning stop remains ena-
bled for 10 min after leaving
the sensor range.
Shower panel
ON
OFF
Disable cleaning stop
1 2 3 4 5 6
The function automatically
stops if no user was detected
for 10 minutes.
You can manually disable the
function following the same
procedure used to enable it.
The fitting will resume normal
operation with a safety delay
of 3 s after you leave the
sensor range.
WimTec OCEAN P7
EN
Warmlauf:
OFF
ON
6 5 4 3 2 1
Reinigungsstopp:
OFF
ON
6 5 4 3 2 1
Hygienespülung:
OFF
ON
6 5 4 3 2 1
Halbautomatik:
OFF
ON
6 5 4 3 2 1
Vollautomatik:
OFF
ON
6 5 4 3 2 1
Manuell:
OFF
ON
6 5 4 3 2 1
29

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

114 720114 683