maintenance required to operate the compressor and other air-operated
tools.
1.BEFORE EYERY USE, inspect the general condition of the tool. Check
for:
- bent needles,
- loose screws,
- misalignment or bending of moving parts,
-clogged nozzle,
- cracked or broken parts,
- any other condition that may affect its safe operation.
2. AFTREEVERY USE, clean the airbrush, according to following
instructions.
J. TROUBLESHOOTING
Airbrush
Problem
Poor Paint Atomization
Will Not Spray
Over spray (Paint Spraying
Further Than Intended)
Nozzle Leakage
Air Leaking from Nozzle
Follow all safety precautions whenever diagnosing or servicing the tool.
Disconnect the air supply before servicing the tool.
Possible Causes
1. Low paint level.
2. Paint not properly thinned. 3.
Clogged nozzle.
4. Loose/damaged needle.
No pressure at the airbrush.
1. Improper application speed.
2. Improper distance from
Work piece.
1. Dirty nozzle.
2. Worn or damaged nozzle.
1. Dirty air valve/seat.
2. Sticky air valve.
3. Damaged air valve spring.
4. Worn/damaged air valve/seat.
- 14 -
Likely Solutions
1. Refill the airbrush with paint.
2. Thin paint.
3. Clean nozzle.
4. Adjust or replace the needle.
Check the air hoses.
1. Move moderately and parallel
to the subject.
2. Adjust the distance from the
intended object.
1. Clean the nozzle.
2. Replace the nozzle and/or
needle.
1. Clean the air valve/seat.
2. Lubricate the air valve/seat.
3. Replace the air valve spring.
4. Replace the air valve.