5.Compressor Protection Function:
(1) After switching from the slush mode or cold drink mode to the power-off
mode, if you restart the slush mode or cold drink mode, the compressor will
have an approximately 3-minute protection period. However, if you unplug
and re-plug the power cord before restarting the machine, it defaults to a
fresh start, and there will be no delay when selecting the slush mode or
cold drink mode again.
(2) When switching from the working mode to the pause state, the
compressor will delay shutting down for approximately 3 minutes.
6.Bucket Securement Safety Function:
(1) If the loading bucket is not properly installed, pressing the"Start"button
will not activate the compressor, fan, or mixing motor, and a warning will be
issued.
(2) Should the loading bucket become detached during operation,the
compressor, fan, and mixing motor will be paused, and a warning will be
issued.
7.Fault Display:
When the slush maker encounters an issue, the display will present an
error code to indicate the specific problem. The error codes and their
corresponding descriptions are as follows:
Error code
E1
E2
E3
E4
E5
E6
Loose Loading Bucket Fault, Mixer Motor Stalling, or Hall
Sensor Communication Failure
Temperature Sensor Open/Short Circuit
Condenser Fan Failure (Open Circuit or Over-current)
Control board and power board communication anomaly
Description
Low sugar alarm
High alcohol alarm
- 22 -