9. Specifications
Permissible ambient conditions
Shock resistance
Vibration resistance
EMC tests
Dielectric strength
Lightning
Leak tightness
Process connection
Bellows sealing
Materials
Wetted materials
Reference chamber
(pressure element)
Process connection
Non-wetted materials
Case and cover
Cable gland
M25 x 1.5
For further specifications see WIKA data sheet SP 60.28 and the order documentation.
■
50 g/11 ms: no contact bouncing at a distance of 200 mbar
from the switch point
■
150 g: no damage in all axes and directions
4 g at a distance of 50 mbar from the switch point, no contact
bouncing (20 ... 100 Hz)
2 kV pin on grounding (case)
■
2 kV pin on pin (micro switch on micro switch)
■
■
1 kV pin on pin within micro switches - 1 minute
7 kV x 1.2/50 μs
≤ 1 x 10
-8
mbar x l/s
≤ 1 x 10
-8
mbar x l/s
Stainless steel, filling with reference gas
G ½ B per EN 837, axial or radial, stainless steel, spanner flats 22 mm
Other connections and connection locations on request
Aluminium die-casting, powder-coated
Plastic, sealing range 5 ... 13 mm; (optional 8 ... 17 mm)
Tightening torque: 8 Nm
EN
25