17.2 Information displaying on LCD screen

Logo blinking means modification
of parameter value
Parameter name

17.3 Professional parameter description

A
rEGu
Default value: Air
Values:
Air / Amb / FLr / FLL
20
tE P
8
.
37
rEGu
Selecting temperature sensor used for the regulation
"Air": Regulation with internal sensor
A
rEGu
"Amb": Regulation with external sensor
An
30
rEGu
r
"FLr": Regulation on floor sensor (external sensor of thermostat, only when
thermostat is connected to master) or embedded sensor on receiver
FL
rEGu
"FLL": Regulation with floor sensor and air sensor
FL
rEGu
Displaying of measured temperature by internal sensor
31
If "Err" is displayed, internal sensor is damaged:
Er
tE P
C
°
A
30
r
30
r
30
b
30
r
30
L
31
r
EN