All other use is considered unsuitable.
We accept no liability for damage caused
through incorrect use.
H Original spare parts
The manufacturer accepts no liability for
damage resulting from the use of parts
other than original spare parts.
▶ Use only original spare parts and
accessories from the manufacturer.
2
Product information
You can expand the connection options of indoor units with the
connection module MC R as follows:
•
Connection of a room controller
•
Connection of input signals for contact switches
(e.g. contact switch, hotel card, window/door contact)
•
Connection of output signals for contact switch
(e.g. alarm system, light)
The product is compatible with the following system
components:
•
Climate 3000i/Line Cool/Logacool AC166i.2
•
Climate 5000i/Easy Cool
•
CRC R-1
The information in the illustrations may vary depending on the
indoor unit.
Importer address:
Thermotechnology Ltd.
Cotswold Way, Warndon
Worcester WR4 9SW / UK
MC R – 6721841757 (2023/03)
2.1
Scope of delivery
Fig. 1:
[1] Connection module MC R with housing
[2] Set of printed documents for product documentation
[3] 2 connection cables to the display
[4] 2 connection cables to the PCB of the indoor unit
[5] Screw for fixing the housing
[6] Cable tie for strain relief
The connection cables have two different lengths.
▶ Use the longer cable for devices with 7 kW.
2.2
Wiring diagram
Fig. 2:
[1] Connection module MC R
[2] Indoor PCB
[3] Indoor unit display
[4] Output signal for alarm, light, etc.
[5] Room controller
[6] Input signal for contact switch
(e.g. hotel card, door/window contact)
Wire of room controller
Brown
Yellow
Black or white
Red
Green/yellow (earth)
Table 1
Terminal assignment of room controller
3
Installation
DANGER
Danger to life from electric shock!
Touching live electrical parts can cause an electric shock.
▶ Before installing this product: disconnect the indoor unit
from the mains voltage.
▶ Before commissioning: mount the covers of the
electronics.
Product information
Terminal
X
Y
E
12V
No connection available
29