charge a defective battery.
6. Operation
6.1 Button functions (Fig. 6)
Item 20: ON/OFF - Units in BAR, KPA, PSI
Item 21: Automatic - Manual - LED
Item 22: START/STOP compressor
Item 23: Increase set value (+)
Item 24: Decrease set value (-)
Item 25: Memory (M1 – M4)
6.2 Switching the equipment On/Off (Fig. 6)
a) Switching on
When you press the button (Item 20), the display
lights up. After it is switched on, the equipment
starts in automatic mode (AUTO appears on the
display).
b) Switching off
Press the button (Item 20) for approx. 3 seconds
until the display switches off .
The equipment switches off automatically after
approx. 5 minutes of non-use.
6.3 Units (Fig. 6)
After switching the equipment on, press the but-
ton (Item 20) several times to select the desired
units: BAR, KPA or PSI.
6.4 Automatic mode (Fig. 6)
Note: This function is available at or above 0.4
bar. If it is not already set, press the button (Item
21) briefl y to select automatic mode (AUTO will
appear on the display). Press the "+" / "-" buttons
(Items 23 / 24) to set the cut-out pressure value.
When you press the "START/STOP" button (Item
22), the compressor will pump until the set pres-
sure is reached and then it will shut off .
6.5 Memory (Fig. 6)
Four memory values (M1 – M4) are available in
automatic mode, to set four diff erent cut-out pres-
sure values. When you press the "M" button (Item
25), "M1" will appear on the display. Press the "+" /
"-" buttons (Items 23 / 24) to increase or decrease
the set value. To save the value, press the "M"
button (Item 25) for a few seconds until the value
fl ashes 2x on the display and is saved. To save
more values, press the "M" button (Item 25) again
and repeat the process.
Anl_CE-CC_18_23_D_Li_SPK13.indb 16
Anl_CE-CC_18_23_D_Li_SPK13.indb 16
GB
6.6 Manual mode (Fig. 6)
Briefl y press the button (Item 21) to select "manu-
al mode" (MAN will appear on the display). When
you press the "START/STOP" button (Item 22),
the compressor will start and the compressor will
stop when you let go of the button.
6.7 LED work light (Fig. 6)
CAUTION! Do not look directly at the LED work
light (Fig. 1 / Item 1)!
Press the button (Item 21) for approx. 3 seconds
to switch on the LED work light.
Press the button (Item 21) again for approx. 3 se-
conds to switch off the LED work light. When the
equipment is not in use, the LED work light will
switch off automatically after 5 minutes.
6.8 Pressure relief button (Fig. 1)
•
To release pressure when the equipment
is switched on, press the button (Item 7)
and hold it until the desired air pressure is
reached.
6.9 Compressor compressed air mode
•
Fit the valve connection (Fig. 1 / Item 4a) of
the compressed air hose on the object you
wish to inflate. Flip over the fastening lever
(Fig. 1 / Item 4b) to secure the valve connec-
tion on the valve or the valve adapter.
•
Depending on what you are inflating, also use
the adapters (10, 11, 12) or other adapters
available from retail stores. The supplied
adapters are located in the drawer (Fig. 2 /
Item 5).
•
Switch on the equipment and consult section
6.3 – 6.7 to adapt the settings to suit your
needs.
•
Warning! Note that in manual mode the com-
pressor does not switch off automatically but
will continue inflating the connected object
until the maximum pressure is reached or the
object bursts.
•
Warning! Observe the information supplied
by the tire manufacturer and the vehicle ma-
nufacturer relating to the recommended tire
pressure.
•
Warning! This equipment is not calibrated!
For a calibrated measurement value, after
you have inflated the tires, check the actual
tire pressure using a suitable gauge, e.g. at a
petrol station.
•
Allow the compressor to cool down for about
10 minutes after every 10 minutes of operati-
on in order to prevent overheating.
- 16 -
05.05.2025 08:40:17
05.05.2025 08:40:17