Operation

a) Select the temperature unit °C/°F at the thermometer/hygrometer
Briefly press the "°C/°F" button of the thermometer/hygrometer to switch between °C (degrees
Celsius) and °F (degrees Fahrenheit).
The temperature display of the outdoor sensor cannot be changed; it always shows
"°C" (degrees Celsius).
b) Maximum/minimum values
Displaying the values
Briefly press the "MAX/MIN" button several times in order to toggle between the following displays:
• Maximum values (indicator "MAX" on display)
• Minimum values ( indicator "MIN" on display)
• Current measured values
If no button is pressed for a few seconds, the current measurement values will auto-
matically appear.
Reset values
Press and hold the "MAX/MIN" button for 3 seconds. Dashes appear in the display (instead of
measurement values) and the saved maximum and minimum values are deleted.
c) Comfort zone indicator
The comfort zone indicator is located at the top of the display. The indicator is generated based on
air humidity and shows you with a glance the current room climate.
"DRY" (dry)
"DRY"/"COMFORT"
"COMFORT" (optimal)
"COMFORT"/"WET"
"WET" (wet)
An arrow below "MORE DRY", "MORE WET" and "NO CHANGE" indicates the trend of
the air humidity; as if the air humidity changes:
"MORE DRY": Air humidity decreases
"MORE WET": Air humidity increases
"NO CHANGE": Air humidity has not changed
A window symbol indicates if you should open the window (
close the window (
- if the air humidity is too low).
Range
The transmission range of the radio signals between outdoor sensor and thermometer/hygrometer
is up to 80 m under optimum conditions.
This transmission range data refers to the so-called "free-field range". However, this
ideal arrangement (e.g. thermometer/hygrometer and outdoor sensor on a plain, even
meadow without trees, houses, etc.) never exists in practice.
Due to the different influences on the wireless transmission, no specific range can be guaranteed.
However, trouble-free operation is usually possible in a single family house.
The range can be significantly reduced by proximity to cables, pipes, metal pieces, electronic
devices, and similar. Thick walls, steel construction, laminated insulated glass windows, etc., also
reduce the range very significantly.
If you notice that the thermometer/hygrometer does not contain any measured values of the out-
door sensor, check the condition of the batteries in the outdoor sensor first. Following that, select
another location for the thermometer/hygrometer and the outdoor sensor.
Maintenance and cleaning
Apart from the occasional battery change, the product is maintenance-free for you.
Use a clean, dry and soft cloth for cleaning. Do not press too hard on the display, this may cause
scratch marks or the display to malfunction; furthermore, the display might break.
Dust can easily be removed using a clean, long-haired brush and a vacuum cleaner.
Do not use abrasive cleaning agents, cleaning alcohol or other chemical solutions, since these
could damage (discolour) the housing or even impair operation.
<34%
35% - 40%
41% - 55%
56% - 64%
>65%
- if the air humidity is too high) or
Disposal
a) General
The product must not be disposed of in the household waste!
Dispose of the waste product in accordance with the applicable legal regulations.
Remove the inserted batteries (or rechargeable batteries),if any, and dispose of them
separately from the product.
b) Batteries and rechargeable batteries
As the end user, you are required by law (battery ordinance) to return all used batteries and re-
chargeable batteries; it is not permitted to dispose of batteries with normal household waste.
Batteries / rechargeable batteries containing hazardous substances are labelled with
this symbol to indicate that disposal in domestic waste is prohibited. The designations
for the heavy metals involved are: Cd = cadmium, Hg = mercury, Pb = lead.
Used batteries, rechargeable batteries and coin cells can be returned to collection points in your
municipality, our stores or wherever batteries / rechargeable batteries / coin cells are sold.
You thereby fulfil your statutory obligations and contribute to the protection of the environment.
Declaration of Conformity (DOC)
We, Conrad Electronic SE, Klaus-Conrad-Straße 1, D-92240 Hirschau, hereby declare that this
product conforms to the fundamental requirements and other relevant regulations of the 1999/5/EC
directive.
The declaration of conformity for this product is available at:
www.conrad.com
Technical data
a) Thermo-/H ygrometer
Power supply ................................................2x batteries of type AAA/Micro
Battery lifespan ............................................Approx. 1 year
Measurement range ....................................Indoor temperature -9.9 °C to +50 °C
.........................................................................Indoor aid humidity 20% to 95% (relative)
If the measured value is lower than the measurement range, "LO" is shown; if it is
higher, "HI" is shown.
Measurement interval .................................Approx. 10 seconds
Dimensions....................................................100 x 165 x 26 mm (W x H x D)
Weight ............................................................192 g (without batteries)
b) Outdoor sensor
Power supply ................................................2x batteries of type AAA/Micro
Battery lifespan ............................................Approx. 1 year
Transmission frequency ..............................433 MHz
Range .............................................................Max. 80 m (see chapter "Range")
Measurement range ....................................Outdoor temperature -39.9 °C to +59.9 °C
.........................................................................Outdoor humidity 20% to 95% (relative)
If the measured value is lower than the measurement range, "LO" is shown; if it is
higher, "HI" is shown.
Measurement interval .................................Approx. 1 minute
Dimensions....................................................40 x 97 x 18 mm (W x H x D)
Weight ............................................................39 g (without batteries)
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represent
the technical status at the time of printing.
© Copyright 2016 by Conrad Electronic SE.

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Dm-7511

Inhaltsverzeichnis