Herunterladen Inhalt Inhalt Diese Seite drucken

Dell PowerEdge 2850 serie Handbuch Seite 11

Aktuelle informationen
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 42
Table 1-4. LCD Status Messages (continued)
Line 1
Line 2
Message
Message
E0D76
BP DRIVE n
1x2 DRIVE FAIL n
SCSI CONNECTOR
EB107
PROC BUS ERR
PROC INIT ERR
PROC PROTOCOL
ERR
EB107
PCIE FATAL ERR
CHIPSET ERR
EB107
MEMORY MIRRORED
EB107
MEMORY SPARED
EFFF2
ROMB PRESENCE
IB110
SBE LOG DISABLED
LOGGING DISABLED
IS000
INTRUSION
NOTE:
For the full name of an abbreviation or acronym used in this table, see the "Glossary"
in your User's Guide.
Causes
Faulty or improperly installed
hard drive or RAID controller.
Faulty or improperly installed
microprocessor or system board.
Faulty or improperly installed
PCI-e card.
Faulty or improperly installed
riser card.
Faulty system board.
Memory mirroring enabled.
Memory spare bank enabled.
Integrated RAID controller is
activated.
System cover has been removed.
Corrective Actions
See "Troubleshooting SCSI Hard
Drives" "Troubleshooting a RAID
Controller Card, " and
"Troubleshooting the Integrated
RAID Controller" in your
Installation and Troubleshooting
Guide.
See "Troubleshooting the
Microprocessors" in your
Installation and Troubleshooting
Guide. If the problem persists, see
"Getting Help" in your
Installation and Troubleshooting
Guide.
Remove and reseat the PCI-e
expansion cards. If the problem
persists, see "Troubleshooting
Expansion Cards" in your
Installation and Troubleshooting
Guide.
Reinstall the expansion-card cage.
See "Installing the Expansion-
Card Cage" in your Installation
and Troubleshooting Guide.
If the problem persists, the riser
card or system board is faulty.
See "Getting Help" in your
Installation and Troubleshooting
Guide.
Information only.
Information only.
Information only.
Information only.
Information only
Information Update
9

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis