Temperature limits (configurable from Airtools on Airzone Cloud). The maximum temperature
can be set in heating mode, and the minimum temperature in cooling mode.
Domestic hot water (DHW) production management. DHW production control enables the
on/off control of production, DHW tank temperature selection and the activation of the high
EN
power function for faster production.
Time schedules. Status, temperature, mode, speed scheduling and DWH.
Cloud integration.
Integration ports. The device features RS-485 standard integration through Modbus RTU and
BACnet MS/TP.
Integration services. The device features Local API and Cloud API integration, Modbus TCP/IP,
Bacnet IP, voice assistants, drivers and mDNS multicast.
Aidoo Pro Air To Water is connected to the AC unit by cable, with a connection process adapted
to the characteristics of each unit. The control and configuration of this device is carried out
via Bluetooth and Wi-Fi Dual (2.4/5 GHz) from the "Airzone Cloud" app (available for iOS and
Android). An external power supply is required to power your Aidoo Pro Air To Water device.
Note: for more information about our products, visit airzonecontrol.com.