Travel profiles
The RolMotion/D+ M drive has two travel profiles, standard
mode and quiet mode.
6.1

Standard mode

When travelling at high speed, only the roller blind slats are
lowered slowly.
This travel is triggered by simply turning on the wall switch/
button.
6.2

Quiet mode

Travel at slow speed along the entire travel path.
This travel is actuated by "double-tapping" at power up
(On - Off - On) or during travel by switching off and on again
in the same direction of travel. The duration of the switched-
off state must be more than one second.
To change to the standard mode travel profile, the drive
must be switched off for one second.
The quiet mode travel profile is not available during the
"Setting the end positions" operation.
6.3
Changing the travel profile
The user can decide whether the default mode or the
whisper mode is to be used for a simple keystroke or an
automatic run command (e.g. from a timer). It the key is
pressed twice, the other travel profile is activated.
Requirements:
• Endpositions are learned
• Changing the travel profile is only possible on upper or
lower limit stop.
• Direction switch ([button UP ▲] or [button DOWN/
CLOSE ▼]) mus be de-energised for at least 2 seconds.
• The other - currently not active - travel profile is activated
by pressing one of the two following button sequences:
►On upper end position
[UP ▲] 1 s, [UP ▲] 1 s, [UP ▲] 1 s,
[DOWN/CLOSE ▼] 1 s,
[DOWN/CLOSE ▼] 1 s,
[DOWN/CLOSE ▼] 3 s.
►On lower end position
[DOWN/CLOSE ▼] 1 s,
[DOWN/CLOSE ▼] 1 s,
[DOWN/CLOSE ▼] 1 s,
[UP ▲] 1 s, [UP ▲] 1 s, [UP ▲] 1 s.
the pauses between the individual keystrokes must not be
longer than 1 s.
Important
For wired control units the run command [button UP ▲] or
[button DOWN/CLOSE ▼] must be aborted manually as
follows:
►On upper end position
[UP ▲] 1 s, [STOP ■],
[UP ▲] 1 s, [STOP ■],
[UP ▲] 1 s, [STOP ■],
[DOWN/CLOSE ▼] 1 s, [STOP ■],
[DOWN/CLOSE ▼] 1 s, [STOP ■],
[DOWN/CLOSE ▼] 3 s.
►On lower end position
[DOWN/CLOSE ▼] 1 s, [STOP ■],
[DOWN/CLOSE ▼] 1 s, [STOP ■],
[DOWN/CLOSE ▼] 1 s, [STOP ■],
[UP ▲] 1 s, [STOP ■],
[UP ▲] 1 s, [STOP ■],
[UP ▲] 3 s.
6 | EN
7
Troubleshooting
Problem /
Error
• The drive does
not start up
• Drive runs only
in one direction
• Drive stops
during travel
• Drive stops
during travel
and then goes
in the opposite
direction
• Drive only
moves in
standard mode
Fig. 7 Troubleshooting the RolMotion/D+ M
8
Servicing
The RolMotion/D+ M is maintenance-free.
9
Service/manufacturer's address
If malfunctions occur or the device is damaged despite
correct handling, contact your contractor.
elero GmbH
Antriebstechnik
Maybachstr. 30
73278 Schlierbach
Deutschland / Germany
Please visit our website if you require a contact partner
outside Germany.
10
Repairs
Please contact your specialist if you have any questions.
Please always provide the following information:
• Item number and designation on the type plate
• Type of fault
• Accompanying conditions
• Your own theories regarding the cause of the problem
© elero GmbH
Possible cause
Remedial ac-
tion
• No power
• Check connec-
supply
tion and elec-
trical voltage
• Allow drive to
• Drive over-
cool down
heated
• Faulty connec-
• Check connec-
tion
tion
• Error when
• Re-program
programming
the end posi-
the end posi-
tions
tions
• End positions
• Re-program
incorrectly
the end posi-
programmed
tions
• Travel to
intermediate
position
• Blind only
• Check the
moves with
smooth run-
difficulty
ning of the
blind
• Obstacle in
drive path
• Re-program
the end posi-
tions
• End positions
• Perform at
are not yet
least two
programmed
complete
movements
in the up and
down direction
without inter-
ruption