Air cooling / ventilation
Working Steps
1.
Marking the recess: to do this, lay the device upside down, flat on the worktop and mark the outline with a sharp
pencil. Observe the dimensions 588 mm x 331 mm and the perpendicularity in the drawing opposite.
2.
Marking opening in the table plate: similarly, the opening in the table plate must also be marked by copying the
already drawn outlines to an inner outline that is scaled down by 5 mm.
3.
Cutting out the opening: cut out the opening in the table plate (see 2.) using a suitable tool. Cleanly carve out the
4 mm recessed area opposite the table surface for the device support with a suitable tool (e.g. a router) since the
corresponding edges remain visible edges. For materials other than wood, please check with your shopfitter for
the correct method.
4. Plugging in supply line: plug the supply line into the device and feed the cable down through the opening in the
table plate. Ensure the plug is secured properly.
5.
Placing the mounting frame: place the device onto the incorporated table edge in the installation position and
check the evenness with the table plate surface together with the glass plate. Rework if necessary. Please note:
the device should be oriented depending on the operating side desired. Consider carefully the ventilation point
as well.
6. Sealing the cut surface: after checking the accuracy of fit, it is recommended to seal the cut surface against the
penetration of fluids.
7.
Laying cable: expertly fix cable in the sideboard under the table plate. Ensure that the cable is not accidentally
chafed by moving parts and subjected to tensile loads. There should be no drawers under the installation device.
8. Masking the surface: it is recommended to mask the joint edges along the glass plate and the worktop surface
with suitable crepe tape sufficiently wide to enable clean and quick operation.
9. Filling joints: grout the constant 2 mm wide circumferential groove evenly with a suitable joint sealer (e.g.
Sikaflex
-221) according to its handling instructions. Joint sealer is not included in the scope of delivery. Please
®
only use materials suitable for food areas! Pay particular attention to selecting suitable joint sealer (e.g.natural
stone silicone) for stone worktops to prevent discolouration. Also ensure an absolutely clean groove to prevent
contamination in the joint sealer.
10. Applying joints neatly: Apply joint sealer with the help of a sealant applicator.
11. Leaving joint sealer to dry: Handle joint sealer according to manufacturer's instructions and leave to dry.